air dried coal sample

Effect of the reignition characteristics on longflame coal by ...

Effect of the reignition characteristics on longflame coal by ...

Experimental system Thermal analysis. The thermal analysis experiment used a STA449C synchronous thermal analyzer. The initial temperature of the experiment was 30 °C; the heating rate was 10 °C/min; the termination temperature was 800 °C; and the mass of coal samples at different immersion times and airdrying times was 25 ± 1 mg.

Effect of water immersion on pore structure of bituminous coal with ...

Effect of water immersion on pore structure of bituminous coal with ...

After the stagnant water is discharged, the residual coal is airdried under the action of air leakage (Fig. 1), forming dried waterimmersed coal (DWIC) [1]. ... For type Ⅲ (the YHP coal sample), the adsorption capacity of the sample continued to increase with increasing relative pressure during the whole adsorption process, and the ...

Development of Multiple Regression Model for Assessment of Coal ...

Development of Multiple Regression Model for Assessment of Coal ...

Moisture content in a coal sample is measured by placing 1 g of airdried coal sample of comminated 212micron size in a petri dish, as shown in Fig. 3a. Further, it is placed in an electric hot air oven and kept at 108 °C along with the lid for 1 h, as illustrated in Fig. 3b. Then, the sample is cooled to room temperature in a desiccator for ...

Coal Calculations | SGS Australia

Coal Calculations | SGS Australia

ADM is Air Dried Moisture (Moisture in the Analysis Sample) NM is Nominated Moisture AR is As Received Basis AD is As Determined (Air Dried) Basis ... Two stage total moisture determination is used when the coal sample is too small mass or too wet to divide or crush without the potential of losing significant amounts of moisture. TMar, % = [Rm ...

Study on pore structure change and lean oxygen reignition ...

Study on pore structure change and lean oxygen reignition ...

At this time, the hightemperature oxidized coal sample in the goaf experienced water immersion and airdrying, and its surface pore structure changed greatly (As shown in Fig. 1). Therefore, the change in oxygen concentration caused by the strength of air leakage under the development of coal and rock mass fissures, and the ratio of coal ...

UNIT III ResearchGate

UNIT III ResearchGate

About 1 gm of powdered, air dried coal sample is heated in silica crucible at 100 to 105 °C for one hour. Percentage of moisture can be calculated from the loss in weight of the coal sample as

Timeshift effect of spontaneous combustion characteristics ... Springer

Timeshift effect of spontaneous combustion characteristics ... Springer

The physical and chemical properties of the airdried residual coal after soaking in the goaf will change, resulting in an increase in its spontaneous combustion tendency. This study aimed to look into the features and mechanism of soakeddried coal's spontaneous combustion. Five samples of coal were dried to various degrees, and the weight loss features during thermal processing were examined ...

Recording Standards or Basis for Coal Analysis

Recording Standards or Basis for Coal Analysis

Asdetermined (airdried) basis: Usually denoted as "adm" or "ADM." Even after airdrying, coal typically contains some moisture, which is referred to as residual moisture. Asreceived basis: Data or results are calculated to the moisture condition of the coal sample when it arrived at the testing facility. Usually denoted as "ar" or "AR."

Experimental Study on Spontaneous Combustion Characteristics of Large ...

Experimental Study on Spontaneous Combustion Characteristics of Large ...

After soaking in water, the volume of the raw coal sample expanded, cracks and pores became more developed, and oxygen absorption was greater after water was removed by drying. ... . 19 pointed out that as the number of active functional groups and the oxidation heat release of the waterimmersed and airdried coal increase, ...

Experimental study of the moisture content influence on CH

Experimental study of the moisture content influence on CH

where M ad represents the airdrying base moisture, %; m and m 1 are the coal sample weight and its lost after the drying, g. The equilibrium moisture ( M e ) is defined as the moisture content when the pore water in the coal sample with ∼ mm pores reaches saturation at a temperature of 30°C and a relative humidity of 96% (using a ...

Minimization of Moisture Readsorption in Dried Coal Samples

Minimization of Moisture Readsorption in Dried Coal Samples

Typical comparison of readsorption curves between the ovendried coal sample and blending of the hot oven (150 C) dried coal sample (500 g) with 200 g of raw (airdried) coal sample.

Characteristics of lean oxygen combustion and dynamic ... ScienceDirect

Characteristics of lean oxygen combustion and dynamic ... ScienceDirect

When processing coal samples, peel off the oxide layer and sieve into 4080 mesh ( mm). To avoid the interference of the original moisture, place the samples in a drying oven to dry for two days. The coal sample was removed and soaked in a conical flask for 200 days and then airdried for 3 days.

PDF Representation of coal and coal derivatives in process modelling SAIMM

PDF Representation of coal and coal derivatives in process modelling SAIMM

That means drying the coal at ambient temperatures or at elevated temperatures not exceeding 40°C (SANS 589:2009, 2009). The apparently dry coal obtained is referred to as 'airdry'. The mass loss from wet coal to 'airdry' coal is referred to as free moisture content. The mass loss when a sample of airdry coal, after proper sample ...

ISO 589:2008(en), Hard coal ? Determination of total moisture

ISO 589:2008(en), Hard coal ? Determination of total moisture

1 Scope. This International Standard describes two methods for determination of the total moisture content of hard coals, a twostage method and a singlestage method. For either method there is a choice between drying in air and drying in a nitrogen atmosphere. Depending on the coal rank, there may be systematic differences between the results ...

Effect of industrial microwave irradiation on the ... ScienceDirect

Effect of industrial microwave irradiation on the ... ScienceDirect

To keep the energy consumption per unit mass of coal dried by hot air the same as that for microwave dried sample, 80 g of the sample with three different kinds of particle sizes was also placed in a drying chamber and the temperature of the drying chamber was kept at 105 °C with a power of kW. Moisture loss was measured by taking out and ...

Proximate Analysis of coal | Coal Analysis Procedure COAL HANDLING PLANTS

Proximate Analysis of coal | Coal Analysis Procedure COAL HANDLING PLANTS

Allow the sample in the air drying cabinet Mix or stir from time to time being careful not to lose and coal particles till weight loss is less than %/h. Record the weight of the tray + sample after air drying cabinet. STAGE II (Residual Moisture) Heat the empty dish at 107 ±3°C and weigh after colling. Pass the air dried sample through 250 ...

Prevention and Control of Spontaneous Combustion of Residual ... Hindawi

Prevention and Control of Spontaneous Combustion of Residual ... Hindawi

The specific experimental steps are as follows. Filling the Sample. Put 50 g samples to be tested into the sample tank, and cover a layer of asbestos with a thickness of 23 mm evenly above the coal sample, filter the air flow to prevent blocking the gas path, tighten the sample tank with screws at both ends, and seal both ends of the sample tank and the inlet and outlet joint with ...

PDF Standard Test Method for Moisture in the Analysis Sample of Coal and Coke

PDF Standard Test Method for Moisture in the Analysis Sample of Coal and Coke

the analysis sample of coal or coke. It is used for calculating other analytical results to a dry basis. When used in conjunction with the air drying loss as determined in accordance with Method D 2013 or Practice D 346, each analytical result can be calculated to an asreceived basis: This standard does not purport to address all of the

Applied Chemistry 2 May 2015 Ques10

Applied Chemistry 2 May 2015 Ques10

(5 marks) 6 (b) gm of air dried coal sample was taken in a crucible, after heating it in an electric oven at 110°C for 1 hr the residue was weighed gm. The residue was heated in Silica crucible covered with vented lid at a temperature 925±257°C for exactly 7 minutes. After cooling the weight of residue was found to contain gm.

Glossary | Ares Asia

Glossary | Ares Asia

ADB AirDried Basis. In coal sample analysis, ADB neglects the presence of moistures other than inherent moisture while DB (drybasis) leaves out all moistures, including surface moisture, inherent moisture, and other moistures. ARB AsReceived Basis. In coal sample analysis, ARB puts all variables into consideration and uses the total ...

Study on pore structure change and lean oxygen reignition ...

Study on pore structure change and lean oxygen reignition ...

After airdrying, capillary agglomeration decreases, resulting in an increase in the total pore volume. In the coal sample treated with O 300 I 200, the inorganic and organic molecules are loose. After immersion in water, the pores of the coal sample are dredged, large pores and throughholes fall off, small pores increase, and pore volume ...

Sontaneous Heating Characteristics of Coal | PDF SlideShare

Sontaneous Heating Characteristics of Coal | PDF SlideShare

Experimental Procedure : About 1g of finely pulverized 212 micron (BSS) airdried coal sample is weighed in a silica crucible and then placed within an electric hot air oven. It is maintained at 110o C. The crucible with the coal sample is allowed to put in the oven for hours and it is taken out with the help of tongues, and then cooled in ...

Coal Sampling Methods | Ensuring the Representative of Coal Sample

Coal Sampling Methods | Ensuring the Representative of Coal Sample

The beginning point and end point should be set in a position which away from the truck 5 meters, and the third point should at the center position. Then digs meters and samples the subsample. That is the manual coal sample method. Workers need to get the sample by the drill.

دریافت اطلاعات بیشتر